Conveyor Idlers
Established in 1976 in China, JUXIN, are
considered as the first Conveyor and components: roller, frame, pulley
manufacturer in Hengshui, China. The rapid growth of the business in
China soon created the need for a distribution depot, therefore in 2007 a
new branch was put in place in Tianjin City The modern day JUXIN now
manufactures conveyor products to suit all supplies of mining, steel
plant, cement plant, quarry, crushing and screening equipment. Our
expertise and knowledge allows us to deliver fully on our promises of
providing quick answers to your enquiries, rapid service, high quality
products and above all, we are fully committed to be the best at what we
do Service Agents are also located in: UK, South Africa, Kenya,
Indonesia, Thailand, Kazakhstan All products are underpinned by
unmatched customer service and prompt, reliable delivery. Our internal
quality systems are designed to ensure that all orders are handled
quickly and are manufactured to the ultimate quality standards. Several
checking processes are in place prior to orders being released from the
factory. Many tightly controlled inspections occur during the production
processed.
Conveyor Idlers,Conveyor Impact Idler,Belt Conveyor Impact Idler,Rubber Cushion Impact Idler Hebei Juxin Conveyor Engineering Co., Ltd , https://www.juxinconveyor.com
This test pen is factory calibrated and ready for use. The following conditions must be recalibrated:
Has been used (or placed) for a long time after calibration;
Electrodes are used frequently;
The measurement accuracy is relatively high;
Do not reuse calibration buffer when making calibrations;
When the pen has a white crystal, it is a normal phenomenon, please do not be nervous, soak it with water for a while;
Drop a few drops of storage solution or calibration buffer inside the pen holder. Do not use distilled or pure water to soak or preserve the test pen.
The test pen glass electrode sensitive bulb may have small air bubbles, which will affect the normal measurement of the electrode. When using, the electrode should be shaken to make the air bubble run out of the sensitive bulb;
The glass electrode is easy to break, so be careful when using it;
If the display value is fuzzy or not displayed or the displayed value is much higher or lower than the true pH of the solution, replace the battery.
2, replace the battery method:
Pull the black plate with the switch on the pen, gently pull it out, do not pull off the wire, you can see four 1.5V batteries, pull out and replace;
Pay attention to the battery polarity and select the same type of battery;
When the electrode is inserted into the test solution or calibration buffer, the maximum height marked on the test pen cannot be exceeded.
If the electrode is left for a long time and the sensitive bulb is exposed to air, the electrode becomes dry, which makes the response slow and the display value unstable. At this time, the electrode should be immersed in distilled water for several hours;
To improve performance, the pH meter electrode is inserted into distilled water at least once a week for a few minutes each time;
Protein precipitates (such as milk, cheese, etc.) should be immersed in pepsin and hydrochloric acid solution for elimination; this solution should be prepared before use. After use, the electrode should be immersed in this solution for several hours and then rinsed with water. Clean, then immersed in distilled water for several hours;
The grease film also affected the measurement of sensitive bulbs. Lee removed the film, washed the sensitive bulb with a 75% alcohol solution, wiped dry with filter paper, rinsed with water, and immersed it in distilled water for several hours.
3. pH calibration Immerse the test pen electrode in a mixed phosphate standard buffer with a pH of 6.86 (at 25°C) and gently shake.
Use a small screwdriver to adjust the potentiometer until the displayed value matches the pH of the standard buffer solution at ambient temperature;
The electrode was inserted into pH 4.01 of potassium phosphate monobasic or pH 9.18 in borax standard buffer;
The displayed value should be within the allowable error range compared to the pH of the buffer solution.
4, the operation steps and methods remove the protective cover;
The electrode of the PH meter is first cleaned with distilled water, and the moisture attached to the electrode is dried with a filter paper;
Switch on the switch on the battery compartment;
Insert the electrode of PH meter into the liquid to be measured until the liquid is immersed slightly below the “immersion lineâ€. If the conditions permit, the solution can be immersed slightly above the “immersion lineâ€;
Gently stir the solution until the value is stable and read the displayed value;
After use, clean the electrode, turn off the switch, and put on the protective cover.
pH meter (acidity meter) and electrode maintenance and precautions Maintenance and precautions of pH meter (acidity meter) and electrode 1. Maintenance and precautions of PH test pen (PH electrode, pen acidity meter):